Ultra-Power series UPS is a three-phase in and three-phase out high-frequency UPS with medium and large power capacity. benefits from the high-efficiency transformer-less double conversion technology. Ultra-Power series can achieve 96% efficiency and high PF1.0 thereby reducing the power and costs it is designed to provide strict voltage regulation, frequency regulation, and zero transfer time for the battery during a power failure making it ideal for small and medium data centers and other critical business applications
Overview Specifications Ordering Information
</snmp,>
Model | CN93350U |
CN93360U |
CN93380U | |
Capacity |
kVA |
50 |
60 | 80 |
Watts |
50K |
60K | 80K | |
Input |
Normal Voltage | 380/400/415Vac (3Ph+N+PE) | ||
Operating voltage range | 140~485Vac for 40% Load; 305~485Vac for Full Load | |||
Harmonic distortion(THDi) | <3%(100% linear load) | |||
Operating frequency range | 40~70Hz | |||
Power factor | ≥0.99 | |||
Bypass voltage range |
220Vac Max.Voltage:+25% (optional +10%,+15%,+20%) 230Vac Max.Voltage:+20%(optional +10%,+15%) 240Vac Max.Voltage:+15%(optional +10%) Min.Voltage:-45%(optional -20%,-30%) |
|||
Bypass Frequency range | Frequency synchronize tracing range:±10% | |||
Generator input | Support | |||
Output |
Rated voltage | 380/400/415Vac (3Ph+N+PE) | ||
Power factor | 0.9 | |||
Voltage regulation | ±1% | |||
Frequency Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) | |||
Frequency Bat. mode | 50/60(±0.1)Hz | |||
Crest factor | 3:1 | |||
Harmonic distortion (THDv) | ≤2% with linear load, ≤4% with non-linear load | |||
Efficiency | 96% | |||
Output Waveform | Pure Sine Wave | |||
Battery |
Rated voltage | ±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs) | ||
Charging current (Charging current can be set according to the battery capacity installed) | 20A | 40A | ||
System Features |
Transfer time | 380/400/415Vac (3Ph+N+PE) | ||
Overload Line mode | ≤110%: Overload 60min, ≤150%: Overload 1min, >150% turn to bypass mode immediately | |||
Overload Bypass mode | 135% Overload long time; 170% Overload 100ms | |||
Backfeed Protection | Support | |||
Alarm | Overload, utility abnormal, UPS fault, battery low, etc | |||
Protection | Short circuit, overload, over-temperature, battery low, fan fault alarm | |||
Remote LCD | Support | |||
Communication | USB, RS232, RS485, Parallel port,dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional) | |||
Environment |
Operating temperature | 0~40°C | ||
Storage temperature | -25~55°C | |||
Humidity range | 0~95% (Non-condensing) | |||
Altitude | <1500m | |||
Noise level | <55dB | <58db | <60db | |
Physical |
Dimension WxDxH(mm) | 828x250x868 | ||
Net Weight (kg) | 80 | 83 | 114 | |
Standards |
Safety | IEC/EN62040-1,IEC/EN60950-1 | ||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
Part Number | Description | ||
CN93350U | 50kVA Double Conversion Transformer-less UPS | ||
CN93360U | 60kVA Double Conversion Transformer-less UPS | ||
CN93380U | 80kVA Double Conversion Transformer-less UPS |