CAT 6 F/FTP 4 PAIR 2...

CAT 6 F/FTP 4 PAIR 23 AWG STEEL WIRE ARMOURED CABLE LSZH

Norden Category 6 F/FTP Steel  Wire Armoured  cables exceed Category 6/ Class E Specification. It is tested  to 250 MHz frequency range and designed to support 10 Gigabyte and External applications to full 100m.Extremely high pair-balance providing excellent EMC(Electro Magnetic Compatibility),minimizing radiation, maximizing noise immunity and providing high alien cross...


Overview Specifications Ordering Information

Overview

Norden Category 6 F/FTP Steel  Wire Armoured  cables exceed Category 6/ Class E Specification. It is tested  to 250 MHz frequency range and designed to support 10 Gigabyte and External applications to full 100m.Extremely high pair-balance providing excellent EMC(Electro Magnetic Compatibility),minimizing radiation, maximizing noise immunity and providing high alien cross...

Specifications

COMPLIANCE

IEEE 802.3an :2006 (10GBASE-T)
ANSI/TIA-568-C.2:2009 Category 6
ISO/IEC-11801, 2nd Edition Class E
IEC 61156-5:2002 Category 6

LSZH: IEC 60332-1, IEC 60754, IEC 61034 

 

 

MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Bare Copper

Conductor Size

0.57 mm, 23 AWG

Conductor Construction

Solid

Insulation Material

SFS PE

Insulation O.D

1.33 mm nom.

Conductor Unit Identification

Solid/Stripe

Colour Code

Per TIA/EIA 568-B

In. Shield Material

Aluminium/Polyester Foil

In. Shield Design

100 % Coverage

Overall Shield Design

100 % Coverage

Overall Foil Shield

Yes

Overall Shield Material

Aluminium/Polyester Foil

Overall Drain-Wire Material

Tinned Copper

Overall Drain-Wire Size

0.41 mm

Overall Drain-Wire Construction

Solid

Total number of Wires

8

Inner Sheath Material

LSZH

Inner Sheath Thickness

0.80±0.2 mm

Armored Material

Steel Wires

Outer Jacket Material

FR-LSZH

Outer Jacket Thickness

1.1±0.4 mm

Outer Jacket Diameter

11.4±1.0 mm

Rip Cord

Yes

Outer Jacket Colour

Per Requirement

Marking

Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range

1 - 250 MHz

Impedance

100 Ω

Coupling Attenuation

85 dB min @ 30-100 MHz 85-20Log (f/100) @100-250 MHz

DC Resistance

73 Ω/km nom.

Max. Resistance Unbalance

4 %

Capacitance

5.6 nF/100m max

Capacitance Unbalance

3.3 pF/m max.

Velocity of Propagation

80 % nom.

Propagation Delay Skew

25 ns/100m max.

Dielectric Strength

1.5 KV/minute

Dielectric Strength to Shield

1.5 KV/minute

Min. Insulation Resistance

5 GΩ•km

Max. Tensile Strength - Short Term

130 N

Min. Bend Radius

50 mm

Operating Temperature Range

-20 °C +60 °C

TRANSMISSION PERFORMANCE

Cat. 6 Screened-pair Horizontal Cables*

Freq.
MHz
Attenuation dB/100m @20 C NEXT
dB
PS   NEXT
dB
RL
dB
ELFEXT
dB
PSELFEXT
dB
1 2.0 80.0 78.0 27.0 81.8 77.8
4 3.8 75.0 72.8 30.0 76.8 73.8
10 6.0 71.0 69.0 30.0 70.0 67.8
20 8.5 62.0 60.2 30.0 58.8 55.8
31.25 10.4 60.9 58.9 28.6 56.8 53.3
100 19.8 54.0 52.0 26.0 47.8 44.8
150 24.7 50.7 48.7 25.1 43.3 40.3
200 29.0 48.1 46.1 23.8 38.8 35.8
250 32.8 46.3 44.3 22.0 36.8 33.8

*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2

Ordering Information

Part Number Description Standard Length

113-20622404X

Cat 6 F/FTP 4 Pair 23 AWG Steel Wire Armoured Cable LSZH

305 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)