Norden Category 6 U/UTP armoured cables exceed Category 6 /Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications to full 100m.Extremely high pair-balance providing excellent EMC (ElectroMagnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair).
Overview Specifications Ordering Information
COMPLIANCEIEEE 802.3an:2006(10GBASE-T) |
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ELFEXT dB |
PSELFEXT dB |
1 | 2.1 | 65.0 | 62.0 | 19.0 | 63.3 | 60.3 |
4 | 4.0 | 63.0 | 60.5 | 19.0 | 51.2 | 48.2 |
8 | 5.7 | 58.2 | 55.6 | 19.0 | 45.2 | 42.2 |
10 | 6.3 | 56.6 | 54.0 | 19.0 | 43.3 | 40.3 |
16 | 8.0 | 53.2 | 50.6 | 18.0 | 39.2 | 36.2 |
20 | 9.0 | 51.6 | 49.0 | 17.5 | 37.2 | 34.2 |
25 | 10.1 | 50.0 | 47.3 | 17.0 | 35.3 | 32.3 |
31.25 | 11.4 | 48.4 | 45.7 | 16.5 | 33.4 | 30.4 |
62.5 | 16.5 | 43.4 | 40.6 | 14.0 | 27.3 | 24.3 |
100 | 21.3 | 39.9 | 37.1 | 12.0 | 23.3 | 20.3 |
200 | 31.5 | 34.8 | 31.9 | 9.8 | 17.2 | 14.2 |
250 | 35.9 | 33.1 | 30.2 | 8.0 | 15.3 | 12.3 |