Norden Category 5e Double jacket cables exceed Category 5e / Class D specification. It is tested to 100 MHz frequency range and designed to support Gigabit 1000Base-T applications up to 100m. Norden Category 5e D/J cables used in digital distribution frames in transmission stations, fixed & portable indoor applications, harsh.
Overview Specifications Ordering Information
COMPLIANCEIEEE 802., IEEE 802.3at for applications |
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material | Bare Copper |
Conductor Size | 0.51 mm, 24 AWG |
Conductor Construction | Solid |
Insulation Material | High Density PE |
Insulation Diameter | 1.03±0.2 mm |
Ind.Shield Material | Aluminium Foil (F/UTP cable) |
Rip Cord | Yes |
Drain Wire | Yes (F/UTP cable) |
Drain Wire Material & Thickness | Tinned copper 0.45 mm |
Conductor Unit Identification | Solid/stripe |
Colour Code. | Per TIA/EIA 568-B |
Total Number of Wires | 8 |
Inner Jacket & Thickness | FR PVC 0.55±0.2 mm |
Outer Jacket | LSZH/FR PVC/PE |
Outer Jacket Thickness & Ex. Diameter | 0.60±0.01 mm, 7.5±0.5 mm |
Outer Jacket Colour | Per Requirement |
Marking | Per Requirement |
Frequency Range | 1 - 100 MHz |
Impedance | 100 Ω ±15 |
Coupling Attenuation | 40 dB min @ 30-100 MHz |
Max. Dc Resistance | 93 Ω/km @ 20 °C |
Max. Resistance Unbalance | 5 % |
Capacitance | 5.6 nF/100m max. |
Capacitance Unbalance | 1.7 pF/m max. |
Velocity Of Propagation | 69 % |
Propagation Delay Skew | 25 ns/100m max. |
Dielectric Strength | 1 KV/minute |
Min. Insulation Resistance | 5 GΩ•km |
Max. Tensile Strength - Short Term | 110 N |
Min. Bend Radius | 60 mm |
Operating Temperature Range | -30 °C +60 °C |
Cat. 5e Horizontal Cables*
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ELFEXT dB |
PSELFEXT dB |
1 | 1.8 | 73.8 | 71.8 | 25.0 | 78.8 | 76.8 |
4 | 3.6 | 64.8 | 62.8 | 28.0 | 66.8 | 64.8 |
10 | 5.8 | 55.3 | 53.3 | 28.0 | 58.8 | 56.8 |
20 | 8.3 | 53.8 | 52.8 | 28.0 | 52.8 | 50.8 |
31.25 | 10.5 | 50.9 | 48.1 | 27.8 | 50.0 | 48.3 |
62.5 | 15.3 | 46.4 | 44.6 | 26.1 | 43.0 | 41.4 |
*Supplied cables meets Cat. 5e min. transmission requirements of IEC 61156-5 Ed. 2
Part Number | Description | Standard Length |
112-21244104X | Category 5e U/UTP 4 Pair D/J Cable FR PVC/ FR PVC | 500 |
112-21213104X | Category 5e U/UTP 4 Pair D/J Cable PVC/ PE | 500 |
112-21244204X | Category 5e F/ UTP 4 Pair D/J Cable FR PVC/ FR PVC | 500 |
112-21213204X | Category 5e F/UTP 4 Pair D/J Cable PVC / PE | 500 |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)