Category 5e F/utp Pa...

Category 5e F/utp Patch Cord

Norden Cat5e patch cords are designed for Electro-magnetic Compatibility, minimizing radiation and maximizing noise immunity. A unique double termination method providing the advantage of both moulded and non-moulded terminations is implemented in this product. High return loss & NEXT loss values ensure low BER (Bit error Ratio) in all application....


Overview Specifications Ordering Information

Overview

Norden Cat5e patch cords are designed for Electro-magnetic Compatibility, minimizing radiation and maximizing noise immunity. A unique double termination method providing the advantage of both moulded and non-moulded terminations is implemented in this product. High return loss & NEXT loss values ensure low BER (Bit error Ratio) in all application....

Specifications

COMPLIANCE

IEEE 802.af, IEEE 802.3at for PoE applications.
ANSI/TIA-568-C.2:2009 Category 5e.
ISO/IEC-11801 2nd Edition Class D.
IEC 61156-6, EN 50173-1; EN 50288-3-2

DESIGN & MATERIALS

Basic Cable Conductor

Stranded Bare Annealed Copper

Wire Insulation

HD PE

Number Of Insulated Conductors

8

Colour Code Of Pairs

Blue x White, Orange x White, Green x White, Brown x White

Individual Pair Shield

Aluminium foil

Overall Shield

Nil

Drain Wire

Yes

Outer Jacket And Boots

LSZH Low Smoke Zero Halogen or PVC

Jacket And Boot Colour

Per Requirement

Standard Surface Marking

Includes Norden P/N, cable description

Cable O.D.

5.3 ± 0.2 mm

Bend Radius

22 mm without load

Storage Temperature

-20 °C to +80 °C

Temperature Operating Range

-20 °C to +75 °C

Flame Test

IEC 60332-1

Halogen Content In LSZH Cables

Null

Wire Scheme

T568B

ELECTRICAL DATA

Impedance @ 1-100MHz

100 ±15 ?

Conductor Resistance

94 ?/km

Contact Resistance

20 M? max.

Resistance Unbalance

2 % max.

Voltage Rating

72 V dc

Dielectric Strength

1 KV/min. rms

Ampacity

1.0 Amps max.

Insulation Resistance

150 M?/Km

Transfer Impedance

N/A

Pair To Ground Capacitance Unbalance

3.3 nF/Km nom.

MECHANICAL & TRANSMISSION DATA

Cable To Plug Tensile Strength

55 N min.

Pulling Force

10 N max.

Durability

750 Mating Cycles

Propagation Delay 1-250MHz

45 ns/100m

MECHANICAL & TRANSMISSION DATA

Freq.
MHz
NEXT(dB) min. RL(dB) min.
2m cord 5m cord 10m cord

1

70.0

70.0

70.0

20.0

4

64.3

63.5

62.4

21.8

8

56.4

55.6

54.7

22.0

10

54.5

53.7

52.8

22.9

16

50.4

49.8

48.9

23.3

20

48.6

47.9

47.1

23.6

30

45.8

45.2

44.6

23.0

60

40.0

39.5

39.1

19.8

100

36.1

35.8

35.6

17.9

Ordering Information