Category 6 F/FTP 4 Pair Cable

Norden Category 6 F/FTP cables exceed Category 6/Class E specification. It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 F/FTP cables are UL listed CM, CMX, CMR & CMP. Data integrity is one of the most essential...


Overview Specifications Ordering Information

Overview

Norden Category 6 F/FTP cables exceed Category 6/Class E specification. It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 F/FTP cables are UL listed CM, CMX, CMR & CMP. Data integrity is one of the most essential...

Specifications

COMPLIANCE

IEEE 802.af,IEEE 802.3at for PoE applications
ANSI/TIA-568-C.2 Category 6
ISO/IEC-11801, Class E
IEC 61156-5: Category 6
LSZH: IEC 60332-1, IEC 60754, IEC 61034

PRODUCT CLASSIFICATION

Product Sequence Premium
Product Type Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material Bare Copper
Conductor Size 0.57 mm, 23 AWG
Conductor Construction Solid
Insulation Material SFS PE
Insulation Diameter 0.51mm
Individual Pair Shield Aluminium Foil (Foil Face Outward), 100 % Coverage
Drain wire Tin-Coated Annealed Copper
Overall Shield Polyester-Aluminium Tape (Foil Face Inward), 100 % Coverage
Outer Jacket LSZH Low Smoke Zero Halogen or PVC
Outer jacket Thickness & Ex. Diameter 0.60±0.05 mm, 7.4±0.4 mm
Rip Cord Yes
Conductor Unit Identification Solid/Stripe
Colour Code Per TIA/EIA 568-B
Total Number of Wires 8
Outer Jacket Colour Per Requirement
Marking Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range 1 - 250 MHz
Impedance 100 Ω ±15
Coupling Attenuation 85 dB min @ 30-100 MHz 85-20 Log (f/100) @100-250 MHz
DC Resistance 73 Ω/km nom.
Max. Resistance Unbalance 4 %
Capacitance 5.6 nF/100m max.
Capacitance Unbalance 3.3 pF/m max.
Propagation Delay Skew 25 ns/1min.
Velocity of Propagation 69 %
Dielectric Strength 1 KV/minute
Min. Insulation Resistance 5 GΩ•km
Max. Tensile Strength - Short Term 110 N
Min. Bend Radius 58 mm
Operating Temperature Range -10°C to +70°C

TRANSMISSION PERFORMANCE

Cat. 6 Screened Pair Horizontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ELFEXT
dB
PSELFEXT
dB
1 2.0 80.0 78.0 27.0 81.8 77.8
4 3.8 75.0 72.8 30.0 76.8 73.8
10 6.0 71.0 69.0 30.0 70.0 67.8
20 8.5 62.0 60.2 30.0 58.8 55.8
31.25 10.4 60.9 58.9 28.6 56.8 53.3
100 19.8 54.0 52.0 26.0 47.8 44.8
150 24.7 50.7 48.7 25.1 43.3 40.3
200 29.0 48.1 46.1 23.8 38.8 35.8
250 32.8 46.3 44.3 22.0 36.8 33.8

*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2

Ordering Information

Part Number Description Standard Length
113-11001404X Category 6 F/FTP 4 Pair Cable PVC 305 mtr
113-11002404X Category 6 F/FTP 4 Pair Cable LSZH 305 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)