Category 6 Unshielde...

Category 6 Unshielded 4 Pair Cable

Norden Category 6 Unshielded cables exceed Category 6/Class E specification. It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 U/UTP cables are UL listed CM, CMX, CMR & CMP and standard packing will be 305m easy pull...


Overview Specifications Ordering Information

Overview

Norden Category 6 Unshielded cables exceed Category 6/Class E specification. It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 U/UTP cables are UL listed CM, CMX, CMR & CMP and standard packing will be 305m easy pull...

Specifications

COMPLIANCE

IEEE 802.af,IEEE 802.3at for PoE applications
ANSI/TIA-568-C.2 Category 6
ISO/IEC-11801, Class E
IEC 61156-5: Category 6
LSZH: IEC 60332-1, IEC 60754, IEC 61034

PRODUCT CLASSIFICATION

Product Sequence Premium
Product Type Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Bare Copper

Conductor Size

0.57 mm, 23 AWG

Conductor Construction

Solid

Insulation Material

High Density PE

Insulation Diameter

1.02±0.03 mm

Conductor Unit Identification

Solid/Stripe

Colour Code

Per TIA/EIA 568-B

Total Number of Wires

8

Rip Cord

Yes

Overall Drain-Wire Material

N/A

Overall Drain-Wire Size

N/A

Overall Drain-Wire Construction

N/A

Outer Jacket

PVC, LSZH or Plenum

Outer Jacket Thickness & Ex. Diameter

0.55±0.05 mm, 6.3±0.4 mm

Outer Jacket Colour

Per Requirement

Marking

Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range

1 - 250 MHz

Impedance

100 ? ±15

Coupling Attenuation

40 dB min @ 30-100 MHz 40-20 Log (f/100) @100-300 MHz

DC Resistance

73 ?/km nom.

Max. Resistance Unbalance

4 %

Capacitance

5.6 nF/100m max.

Capacitance Unbalance

3.3 pF/m max.

Propagation Delay Skew

35 ns/100m max.

Velocity of Propagation

69 %

Dielectric Strength

1 KV/minute

Min. Insulation Resistance

5 G?•km

Max. Tensile Strength - Short Term

110 N

Min. Bend Radius

53.6 mm

Operating Temperature Range

-10°C to +65°C

TRANSMISSION PERFORMANCE

Cat. 6 Un-screened Pair Horizontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ELFEXT
dB
PS.ACRF
dB

1

1.9

87.6

82.6

28.0

85.0

80.0

4

3.5

79.2

74.2

30.0

73.0

68.0

10

5.6

73.3

68.3

29.0

65.0

60.2

20

8.4

69.1

63.8

29.0

59.0

54.0

31.25

10.0

66.0

61.1

28.6

55.1

50.3

100

18.9

58.0

53.0

25.1

45.0

40.1

150

24.0

55.2

50.7

23.8

41.8

36.9

200

26.1

53.0

48.0

22.8

39.0

33.8

250

30.0

52.6

47.6

22.0

37.8

32.8

*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2

Ordering Information