Norden Category 6 U/UTP armoured cables exceed Category 6 /Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications to full 100m.Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance...
Overview Specifications Ordering Information
COMPLIANCEIEEE 802.3an:20006(10GBASE-T) |
Conductor Material |
Annealed Bare Copper |
Conductor Size |
0.57 mm, 23 AWG |
Conductor Construction |
Solid |
Insulation Material |
HDPE |
Insulation O.D |
1.05 mm nom. |
Conductor Unit Identification |
Solid/Stripe |
Colour Code |
Per TIA/EIA 568-B |
Conductor Unit Lay-Up |
Pairs |
Total Number Of Wires |
8 |
Separator |
PE |
Inner Jacket Material |
HDPE |
Armour |
ECCS Tape |
Armour Thickness |
≥ 0.125mm |
Outer Jacket Material |
HDPE |
Outer Jacket Thickness & Ex. Diameter |
10.7±0.4 mm |
Outer Jacket Colour |
Per Requirement |
Conductor Resistance @20°C |
Max. 93.8 Ω/KM |
Conductor Resistance Unbalance |
Max. 5 % |
Mutual Capacitance @1KHZ |
Max. 56 nF/KM |
Insulation Resistance |
min. 5000 MΩ.km |
High Voltage |
2.5 Kv DC/1 min |
Capacitance Earth Unbalance |
Max. 3300 pF/km |
Propagation Delay @ 1, 10, 100 &250 MHz |
Max. 570, 545,538 & 536ns/100 m |
Propagation DeLay Skew 1 – 250 MHz |
Max. 45 ns/100 m |
Characteristic Impedance (1-250 MHz) |
25 ns/100m max. |
Bending Radius |
20x Diameter(min.) |
Pulling Force |
11.5 kgs(max.) |
Temperature Range |
-20°C up to +60°C |
Cat. 6a Un-screened Pair Horizontal Cables*
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ELFEXT dB |
PSELFEXT dB |
1 | 2.1 | 65.0 | 62.0 | 19.0 | 63.3 | 60.3 |
4 | 4.0 | 63.0 | 60.5 | 19.0 | 51.2 | 48.2 |
8 | 5.7 | 58.2 | 55.6 | 19.0 | 45.2 | 42.2 |
10 | 6.3 | 56.6 | 54.0 | 19.0 | 43.3 | 40.3 |
16 | 8.0 | 53.2 | 50.6 | 18.0 | 39.2 | 36.2 |
20 | 9.0 | 51.6 | 49.0 | 17.5 | 37.2 | 34.2 |
25 | 10.1 | 50.0 | 47.3 | 17.0 | 35.3 | 32.3 |
31.25 | 11.4 | 48.4 | 45.7 | 16.5 | 33.4 | 30.4 |
62.5 | 16.5 | 43.4 | 40.6 | 14.0 | 27.3 | 24.3 |
100 | 21.3 | 39.9 | 37.1 | 12.0 | 23.3 | 20.3 |
200 | 31.5 | 34.8 | 31.9 | 9.8 | 17.2 | 14.2 |
250 | 35.9 | 33.1 | 30.2 | 8.0 | 15.3 | 12.3 |
*Supplied cables meets Cat. 6 min. transmission requirements of IEC 61156-5 Ed. 2