CATEGORY 6A U/UTP 23...

CATEGORY 6A U/UTP 23 AWG 4 PAIR CABLE HFFR

Norden Category 6A UTP cables exceed Category 6A / Class EA specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000 Base-T and 1000Base-Tx applications up to 100m.Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity, and providing high alien...


Overview Specifications Ordering Information

Overview

Norden Category 6A UTP cables exceed Category 6A / Class EA specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000 Base-T and 1000Base-Tx applications up to 100m.Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity, and providing high alien...

Specifications

PRODUCT CLASSIFICATION

Product Sequense

Euro Class

Product Type

Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Bare Copper

Conductor Size 

23 AWG

Conductor Construction

Solid 

Insulation Material

PE 

Insulation O.D.

1.03 mm nom.

Colour Code

Per TIA/EIA 568-B

Conductor Unit Lay-Up

Pairs 

Total Number of Wires

8

Outer Jacket Material

HFFR

Outer jacket Diameter

6.5 ± 0.20 mm

Outer Jacket Colour

Per requirement

Rip Cord

Yes 

ELECTRICAL & MECHANICAL CHARACTERISTICS

Pulling Force

110 N/mm²max.

Delay Skew

< 45 ns / 100 m

Characteristic Impedance

100 ± 5 Ω @ 100 MHZ

DC Resistance

< 9.5 Ω / km

Resistance Unbalance

< 2% max.

Capacitance

< 60 pF / m

Cap. Unbalance (Wire to Ground) 

1600 pF/Km 

Velocity of Propagation (NVP)

66 % 

Insulation Resistance

5000 MΩ x m

Transfer Impedance

N/A

Short Term Bend Radius

50 mm

Long Term Bend Radius 

25 mm 

Min. Impact 

 10 Impacts

Min. Crush Resistance

1000 N/10 cm

Max. Tensile Strength 

90 N 

Test Voltage

1000 V

Operating Voltage

125 V

Operating Temperature Range

-20°C to +70°C

Installation Temperature

0°C to +50°C

 

TRANSMISSION PERFORMANCE

Cat. 6A Un-screened Pair Horizontal Cables*
 
Freq.
MHz
Attenuation (dB/100m)  NEXT(dB)  PS-NEXT(dB)  ACR (dB/100m)  PS-ACR (dB/100m) ACRF (dB/100m) PS-ACR (dB/100m) Return Loss (dB)
1 2.0 95.0 92.0 90.0 87.0  100 97.0 25.0
4 3.6 95.0 92.0 90.0 87.0 100 97.0 25.0 
10 5.4 95.0 92.0 85.0 82.0  90.0 87.0 28.0
100 18.3 87.0 84.0 75.0 72.0 75.0 72.0 25.0
200 25.0 87.0 84.0 75.0 72.0 70.0 67.0 25.8
250 29.1 85.0 82.0 52.0 49.0 65.0 62.0 23.0 
400  37.4 75.0 72.0 41.0  48.0 55.0 52.0 23.0 
500 41.5 75.0 72.0 30.0  27.0 55.0 52.0 21.0
*Supplied cables meets Cat. 6a min. transmission requirements as per IEC 61156-5 Ed. 2

Ordering Information