Norden augmented Category 6 unshielded patch cord delivers optimal transmission & networking performance with reduced Insertion loss and Alien crosstalk. This is fully backward compatible to Category 6 (Class E) and Category 5E (Class D) products_backup and maximizes productivity levels 10 times the data throughput of Category 6.Each patch cord is tested with Fluke tester and individual cover include with the report. This Patch cord is tested for transmission frequencies up to 500 MHz and compatible with the 10 Gigabits applications, including the following protocols: Gigabit 1000 BASE-T; 100 BASE-T; 10 BASE-T (IEEE 802.3) 4/16 Mbps Token Ring (IEEE 802.5); 100 VG-Any LAN100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM Voice.
Overview Specifications Ordering Information
IEEE 802.af and IEEE 802.3at for PoE applications
IEEE 802.3an-2006, and ISO 11801 Class EA channel standards
IEC 60603-7, ISO/IEC-11801, ANSI/TIA-968-A,ANSI/TIA-568-C.2
Category 6A
Basic Cable Conductor |
Stranded Bare Annealed Copper |
Conductor size |
24 AWG |
Wire Insulation |
SFS PE |
Jack Contact |
Gold over Nickel |
Number Of Insulated Conductors |
8 |
Colour Code Of Pairs |
Blue x White, Orange x White, Green x White, Brown x White |
Overall Shield |
Nil |
Outer Jacket and Boots |
LSZH (Low Smoke Zero Halogen) or PVC |
Jacket And Boot Colour |
Per requirement |
Standard Surface Marking |
Includes Norden P/N, cable description |
Cable O.Diameter |
6.0 ± 0.2 mm |
Bend Radius |
> 25 mm without load |
Storage Temperature |
-20 °C to +80 °C |
Temperature Operating Range |
-20 °C to +75 °C |
Flame Test |
IEC 60332-1 |
Wire Scheme |
T568B |
Impedance @ 1-250 MHz |
100 ±15 Ω |
Impedance @ 250-500 MHz |
100 ±18 Ω |
Conductor Resistance |
< 73 Ω/km |
Contact Resistance |
20 MΩ Max. |
Resistance Unbalance |
2 % max. |
Voltage Rating |
72 V dc |
Dielectric Strength |
1 KV/min. rms |
Ampacity |
1.0 Amps max. |
Insulation Resistance |
150 MΩ/Km |
Transfer Impedance |
N/A |
Pair to Ground Capacitance Unbalance |
3.3 nF/Km nom. |
Cable To Plug Tensile Strength |
96 N min. |
Pulling Force |
10 N max. |
Durability |
1000 Mating Cycles |
Propagation Delay 1-250 MHz |
< 25 ns/100m |
Freq. MHz |
NEXT(dB) min. | RL(dB) min. | |||
1m cord | 2m cord | 5m cord | 10m cord | ||
1 | 65.0 | 65.0 | 65.0 | 65.0 | 19.5 |
4 | 65.0 | 65.0 | 65.0 | 65.0 | 21.0 |
10 | 64.9 | 64.8 | 64.2 | 62.8 | 22.0 |
20 | 60.7 | 60.1 | 58.7 | 57.3 | 23.0 |
30 | 56.9 | 56.3 | 54.9 | 53.6 | 23.0 |
60 | 51.0 | 50.4 | 49.2 | 48.1 | 20.0 |
100 | 47.0 | 46.4 | 45.4 | 44.5 | 18.0 |
200 | 41.1 | 40.7 | 39.9 | 39.3 | 15.0 |
250 | 39.3 | 38.9 | 38.1 | 37.7 | 14.0 |
300 | 36.4 | 36.2 | 35.9 | 35.8 | 12.5 |
400 | 31.2 | 31.6 | 32.0 | 32.4 | 10.5 |
500 | 27.8 | 28.2 | 28.5 | 29.4 | 9.2 |