Norden Category 7A S/FTP cables exceed Category 7A/Class FA specification, maximizing the user’s return on investment, by extending the life of the system. It is tested to 1000MHz frequency range and designed to support Broadband CATV and other 10 Gigabyte applications. Data integrity is one of the most essential network...
Overview Specifications Ordering Information
COMPLIANCEIEEE 802.3an :2006 (10GBASE-T) |
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material |
Bare Copper |
Conductor Size |
23 AWG |
Normal Conductor Diameter |
0.57±0.005 mm |
Conductor Construction |
Solid |
Insulation Material |
SFS PE |
Insulation O.D. |
1.35 mm nom. |
Conductor Unit Identification |
Solid/Stripe |
Colour Code |
Per TIA/EIA 568-B |
Ind. Shield Material |
Aluminium/Polyester Foil |
Ind. Shield Design |
Aluminium Face Outwards |
Conductor Unit Lay-Up |
Pairs |
Drain Wire |
N/A |
Overall Shield Design |
Braid |
Overall Shield Material |
Tinned Copper 0.10 mm |
Braid Coverage |
More than 40 %. |
Total Number of Wires |
8 |
Rip Cord |
yes |
Outer Jacket Material |
LSZH Low Smoke Zero Halogen or PVC |
Outer Jacket Thickness & Ex. Diameter |
0.55±0.05 mm, 7.9±0.5 mm |
Outer Jacket Colour |
Per Requirement |
Marking |
Per Requirement |
Frequency Range |
1 - 1000 MHz |
Impedance |
100 Ω |
Max. DC Resistance |
73 Ω/km @ 20 °C |
Max. Resistance Unbalance |
2 % |
Capacitance |
44 pF/m |
Capacitance Unbalance |
1.2 pF/m max. |
Velocity of Propagation |
78 % nom. |
Propagation Delay Skew |
25 ns/100m max. |
Dielectric Strength |
1.5 kV/minute |
Dielectric Strength to Shield |
1.5 kV/minute |
Min. Insulation Resistance |
5 GΩ•km |
Coupling Attenuation |
85 db min @ 30-100 MHz 85-20 log (f/100) @100-1000 MHz |
Max. Tensile Strength - Short Term |
130 N |
Min. Bend Radius |
60 mm |
Operating Temperature Range |
+80 °C to -20 °C |
Cat.7A Screened Horizontal Cables*
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ACR dB |
ELFEXT dB |
PS.ACRF dB |
1 |
2.0 |
100.0 |
97.0 |
27.0 |
98.0 |
91.0 |
88.0 |
4 |
3.4 |
99.8 |
96.8 |
30.0 |
96.4 |
91.0 |
88.0 |
10 |
5.3 |
99.3 |
96.3 |
30.0 |
94.0 |
90.4 |
87.4 |
20 |
7.3 |
99.1 |
95.0 |
30.0 |
91.8 |
88.6 |
85.6 |
31.25 |
9.1 |
99.0 |
94.5 |
29.8 |
89.9 |
87.3 |
84.3 |
100 |
17.1 |
98.7 |
93.6 |
26.0 |
81.5 |
84.4 |
81.5 |
150 |
21.0 |
96.5 |
93.0 |
26.0 |
75.5 |
82.5 |
79.3 |
200 |
25.0 |
95.2 |
92.2 |
26.0 |
70.2 |
80.0 |
77.0 |
250 |
28.7 |
94.8 |
92.8 |
25.6 |
66.1 |
77.0 |
74.0 |
300 |
31.0 |
93.3 |
91.3 |
25.6 |
62.3 |
74.8 |
71.8 |
400 |
33.4 |
91.9 |
90.0 |
25.0 |
58.5 |
69.0 |
67.2 |
500 |
38.0 |
89.9 |
88.9 |
25.0 |
51.9 |
66.6 |
64.6 |
600 |
43.1 |
86.1 |
86.0 |
25.0 |
43.0 |
62.0 |
60.0 |
1000 |
57.5 |
82.0 |
81.0 |
23.0 |
24.5 |
48.1 |
45.1 |
*Supplied cables meets Cat. 7a min. transmission requirements as per IEC 61156-5 Ed. 2
Part Number | Description | Standard Length |
116-10002504X |
Category 7a S/FTP 4 Pair Cable LSZH |
305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)