EUROPOWER SERIES-6-20kVA Single Phase Online UPS

Europower series (CellNor Euro Power) single-phase true double conversion design Online UPS is for commercial devices, enterprise server and high-end equipment. Compact size design to have bigger power density for expected space utilization. Suit for the enterprise server room and precious equipment with high reliability and high power quality demand. CellNor Online UPS can be used to supply vital important equipment such as medical analysis equipment, operating rooms in hospitals, ultrasound equipment, security systems, all kinds of automation systems, computer networks and communications.


Overview Specifications Ordering Information

Overview

Europower series (CellNor Euro Power) single-phase true double conversion design Online UPS is for commercial devices, enterprise server and high-end equipment. Compact size design to have bigger power density for expected space utilization. Suit for the enterprise server room and precious equipment with high reliability and high power quality demand. CellNor Online UPS can be used to supply vital important equipment such as medical analysis equipment, operating rooms in hospitals, ultrasound equipment, security systems, all kinds of automation systems, computer networks and communications.

Specifications

GENERAL FEATURES

  • True Double Conversion

  • Microprocessor Control Optimizes Reliability

  • Input Power Factor Correction

  • Output Power Factor 0.9

  • Wide Input Voltage (110V-300V)

  • Converter Mode Available

  • ECO Mode for Energy Saving

  • Generator Compatible

  • Smart SNMP, USB, RS-232

  • Comprehensive Display

  • Easy Monitoring and Access of UPS Status

  • Soft Start Capacity

  • Transformer Free Design, IGBT PWM Controlled

Model CNE-2006OU CNE-2010OU CNE-2020OU

Capacity

6 KVA / 5.4 kW

10 KVA / 9 kW

20 KVA / 18 kW

Input

Nominal Voltage

220/230/240 Vac (or 110/120/127 Vac)

Voltage Range

±30% at Full Load

Frequency Range

50 Hz / 60 Hz ±10%

Power Factor

≧ 0.99 @ Nominal Voltage (100% load)

Output

Output Voltage

220/230/240 Vac (or 110/120/127 Vac)

Voltage Regulation

± 1%

Frequency Range

50 Hz / 60 Hz ±1%

Overload

100%-125% for 5 min, 125%-150% for 60 Sec, >150% Transfer to Bypass

Inverter Crest Ratio

3:1

Harmonic Distortion (THDv)

≦3 % THD (Linear Load), ≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode

Zero

Inverter to Bypass

Zero

Waveform (Batt. Mode)

Pure Sinewave

Efficiency

AC Mode

92%

Battery Mode

90%

Battery

Standard
Model

Battery Type

12 V / 7 Ah

12 V / 9 Ah

No Internal Batteries 9 Ah External

Numbers in string

16                                                                                                      16x2

Typical Recharge Time

7 hours recover to 90% capacity

Charging Current (max.)

2A

Long-run
Model

Battery Type

Depending on the capacity of external batteries

Numbers in string

16 or 20pcs

Charging Current (max.)

8 A (Adjustable)

Indicators

LCD Panel

Load level, Battery level, Line mode, Battery mode, Bypass mode, ECO mode and Fault indicators

Alarm

Battery Mode

Beeps every 4 seconds

Low Battery

Beeps every second

Overload

Beeps twice per second

Fault

Continously beeping

Environment

Humidity

0-95 % RH @ 0- 50°C (non-condensing)

Noise Level

Less than 55dBA @ 1 Meter

Physical

Standard
Model

Dimensions (WxDxH)

300x550x750

300x550x750

300x650x700

Weight (kg)

70

78

42

Long-run
Model

Dimensions (WxDxH)

300x550x350

300x550x350

300x650x700

Weight (kg)

28

36

42

 

Ordering Information

Part Number Description

CNE-2006OU

6 kVA Single Phase Online UPS

CNE-2010OU

10 kVA Single Phase Online UPS

CNE-2020OU

20 kVA Single Phase Online UPS