Europower series (CellNor Euro Power) single-phase true double conversion design Online UPS is for commercial devices, enterprise server and high-end equipment. Compact size design to have bigger power density for expected space utilization. Suit for the enterprise server room and precious equipment with high reliability and high power quality demand. CellNor Online UPS can be used to supply vital important equipment such as medical analysis equipment, operating rooms in hospitals, ultrasound equipment, security systems, all kinds of automation systems, computer networks and communications.
Overview Specifications Ordering Information
GENERAL FEATURES
True Double Conversion
Microprocessor Control Optimizes Reliability
Input Power Factor Correction
Output Power Factor 0.9
Wide Input Voltage (110V-300V)
Converter Mode Available
ECO Mode for Energy Saving
Generator Compatible
Smart SNMP, USB, RS-232
Comprehensive Display
Easy Monitoring and Access of UPS Status
Soft Start Capacity
Transformer Free Design, IGBT PWM Controlled
Model | CNE-2006OU | CNE-2010OU | CNE-2020OU | ||
Capacity |
6 KVA / 5.4 kW |
10 KVA / 9 kW |
20 KVA / 18 kW |
||
Input |
Nominal Voltage |
220/230/240 Vac (or 110/120/127 Vac) |
|||
Voltage Range |
±30% at Full Load |
||||
Frequency Range |
50 Hz / 60 Hz ±10% |
||||
Power Factor |
≧ 0.99 @ Nominal Voltage (100% load) |
||||
Output |
Output Voltage |
220/230/240 Vac (or 110/120/127 Vac) |
|||
Voltage Regulation |
± 1% |
||||
Frequency Range |
50 Hz / 60 Hz ±1% |
||||
Overload |
100%-125% for 5 min, 125%-150% for 60 Sec, >150% Transfer to Bypass |
||||
Inverter Crest Ratio |
3:1 |
||||
Harmonic Distortion (THDv) |
≦3 % THD (Linear Load), ≦5 % THD (Non-linear Load) |
||||
Transfer Time |
AC Mode to Battery Mode |
Zero |
|||
Inverter to Bypass |
Zero |
||||
Waveform (Batt. Mode) |
Pure Sinewave |
||||
Efficiency |
AC Mode |
92% |
|||
Battery Mode |
90% |
||||
Battery |
Standard |
Battery Type |
12 V / 7 Ah |
12 V / 9 Ah |
No Internal Batteries 9 Ah External |
Numbers in string |
16 16x2 |
||||
Typical Recharge Time |
7 hours recover to 90% capacity |
||||
Charging Current (max.) |
2A |
||||
Long-run |
Battery Type |
Depending on the capacity of external batteries |
|||
Numbers in string |
16 or 20pcs |
||||
Charging Current (max.) |
8 A (Adjustable) |
||||
Indicators |
LCD Panel |
Load level, Battery level, Line mode, Battery mode, Bypass mode, ECO mode and Fault indicators |
|||
Alarm |
Battery Mode |
Beeps every 4 seconds |
|||
Low Battery |
Beeps every second |
||||
Overload |
Beeps twice per second |
||||
Fault |
Continously beeping |
||||
Environment |
Humidity |
0-95 % RH @ 0- 50°C (non-condensing) |
|||
Noise Level |
Less than 55dBA @ 1 Meter |
||||
Physical |
Standard |
Dimensions (WxDxH) |
300x550x750 |
300x550x750 |
300x650x700 |
Weight (kg) |
70 |
78 |
42 |
||
Long-run |
Dimensions (WxDxH) |
300x550x350 |
300x550x350 |
300x650x700 |
|
Weight (kg) |
28 |
36 |
42 |
Part Number | Description | ||
CNE-2006OU |
6 kVA Single Phase Online UPS |
||
CNE-2010OU |
10 kVA Single Phase Online UPS |
||
CNE-2020OU |
20 kVA Single Phase Online UPS |