EUROPOWER SERIES-Tower Type 1-3kVA Online UPS

Europower series single-phase true double conversion design Online UPS is for commercial devices, enterprise server andhigh-end equipment. Compact size design to have bigger power density for expected space utilization. Suit for theenterprise server room and precious equipment with high reliability and high power qualitydemand. CellNor Online UPScan be used to supply vital important equipment such as medical analysis equipment, operating rooms in hospitals,ultrasound equipment, security systems, all kinds of automation systems, computer networks and communications.


Overview Specifications Ordering Information

Overview

Europower series single-phase true double conversion design Online UPS is for commercial devices, enterprise server and
high-end equipment. Compact size design to have bigger power density for expected space utilization. Suit for the
enterprise server room and precious equipment with high reliability and high power qualitydemand. CellNor Online UPS
can be used to supply vital important equipment such as medical analysis equipment, operating rooms in hospitals,
ultrasound equipment, security systems, all kinds of automation systems, computer networks and communications.

Specifications

GENERAL FEATURES

  • True Double Conversion

  • Microprocessor Control Optimizes Reliability

  • Input Power Factor Correction

  • Output Power Factor 0.9

  • Wide Input Voltage (120V-300V)

  • Converter Mode Available

  • ECO Mode for Energy Saving

  • Generator Compatible

  • Smart SNMP, USB, RS-232

  • Comprehensive Display

  • Easy Monitoring and Access of UPS Status

  • Soft Start Capacity

 
Model CNE-2001OU CNE-2002OU CNE-2003OU

Capacity

VA

1000

2000

3000

Watts

900

1800

2700

Phase

Single phase with ground

Input

Normal voltage

220/230/240 Vac (or 110/120/127 Vac)

Operating voltage range

±30% at Full Load

Operating Frequency Range

50Hz/60Hz ±10%

Power factor

≧ 0.99 @ Nominal Voltage (100% load)

Output

Output voltage

220/230/240 Vac

Voltage Regulation

± 1%

Frequency Range (Synchronized Range)

47~ 53 Hz or 57 ~ 63 Hz

Overload

100%-125% for 5 min, 125%-150% for 60 Sec, >150% Transfer to Bypass

Inverter Crest Ratio

3:1

Harmonic Distortion (THDv)

≦3 % THD (Linear Load), ≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode

Zero

Inverter to Bypass

Zero

Waveform (Batt. Mode)

Pure Sinewave

Efficiency

AC Mode

92%

Battery Mode

90%

Battery

Standard
Model

Battery Type

12 V / 9 Ah

12 V / 9 Ah

12 V / 9 Ah

Numbers in string

2

4

6

Typical Recharge Time

4 hours recover to 90% capacity

Charging Current (max.)

1A

Charging Voltage

27.4 Vdc ± 1%

54.7 Vdc ±1%

82.1 Vdc ±1%

Long-run
Model

Battery Type

Depending on the capacity of external batteries

Numbers in string

3

6

8

Charging Current (max.)

6A (Adjustable)

Charging Voltage

41.3 Vdc ±1%

82.1 Vdc ±1%

109.4 Vdc ±1%

Indicators

LCD Panel

Load level, Battery level, Line mode, Battery mode, Bypass mode, ECO mode and Fault indicators

Alarm

Battery Mode

Beeps every 4 seconds

Low Battery

Beeps every second

Overload

Beeps twice per second

Fault

Continously beeping

Environment

Humidity

0-95 % RH @ 0- 40°C (non-condensing)

Noise Level

Less than 50dBA @ 1 Meter

Physical

Standard
Model

Dimensions (WxDxH)

150x400x250

200x500x350

200x500x350

Weight (kg)

14

28

32

Long-run
Model

Dimensions (WxDxH)

150x400x250

200x500x350

200x500x350

Weight (kg)

6

11

12

 

Ordering Information

Part Number Description

CNE-2001OU

1 kVA Single Phase Online UPS

CNE-2002OU

2 kVA Single Phase Online UPS

CNE-2003OU

3 kVA Single Phase Online UPS