MAX-POWER SERIES-Onl...

MAX-POWER SERIES-Online Transformerless 10kVA UPS

Maxpower Series is a small to medium power transformer-less UPS of CellNor. This is an online double conversion UPS with power factor of 0.9. The CN7310MP model supports ECO operation mode.  


Overview Specifications Ordering Information

Overview

Maxpower Series is a small to medium power transformer-less UPS of CellNor. This is an online double conversion UPS with power factor of 0.9. The CN7310MP model supports ECO operation mode.

 

Specifications

   GENERAL FEATURES

  • Online double conversion with DSP control
  • Wide input range:208~478Vac
  • Wide input frequency range:40~70Hz
  • Support parallel function(Optional)
  • Optimization battery group, the quantity of battery:16/18/20pcs
  • Support 3/1 and 1/1 operation
  • Maximum charging current up to 14A(Settable)
  • ECO mode operation for energy saving
  • Intelligent fan speed regulation
  • Cold start
  • Self-testing when UPS start-up 
Model CN7310MP

Capacity

VA

1000

Watts

9000

Input

Normal Voltage

380/400/415Vac; (3Ph+N+PE), 220/230/240Vac (L+N+PE)

Operating Voltage Range

208~478Vac;120~276Vac

Operating Frequency Range

40~70Hz (50/60Hz Auto-Sensing)

Power Factor

≥0.99 

Bypass voltage range

Max.voltage: 220V: +25%(optional +10%,+15%,+20%)
230V: +20% (optional +10%,+15%)
240V: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)

Bypass frequency range

50/60Hz±10%

Generator input

Support

Output

Rated voltage

220/230/240Vac

Power factor

0.9

Voltage Regulation

±1%

Frequency

Line mode

±1%/±2%/±4%/±5%/±10% of the rated frequenc y(optional)

Bat. mode

50/60(±0.1)Hz

Crest Factor

3:1

Harmonic Distortion (THDv)

≤2% with linear load, ≤5% with non-linear load

Efficiency

>93.5%

Battery

Battery voltage

192/216/240Vdc

Capacity (Standard unit)

12V/7Ah/9Ah

Typical recharging time

6~8 hours (to 90% of full capacity)

Charging current

1.35A (standard unit) ; Max.current 14A(Long run unit)

System
Features

Transfer time

AC mode to Bat.Mode:0ms,Inverter to Bypass:0ms

Overload

Line mode

Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% tur n to bypass mode immediately

Bypass mode

63A(Breaker)

Short circuit

Hold whole system

Overheat

Line mode: Turn to bypass; Backup mode: shut down UPS immediately

Battery low

Alarm and switch off

Self-diagnostics

Upon power on and software control

Battery

Advanced battery management

Audible & Visual alarms

Line failure, Battery under voltage, Overload, System fault

LED & LCD display

Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS fault

LCD display

Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage,
Inner temperature & Remaining battery backup time

Communication interface

Rs232, USB, SNMP card (optional), Parallel board (optional), Relay card (optional)

Environment

Operating temperature

0~40°C

Storage temperature

-25~55°C

Humidity range

0~95% (Non-condensing)

Altitude

<1500m

Noise level

<55dB

Physical

Dimension

E: 220 x 531 x 450 ; I:250 x 900 x 868

Weight

22/114

 

 
STANDARDS      

 

Safety

IEC/EN62040-1, IEC/EN60950-1

EMC

IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

       

Ordering Information

Part Number Description

CN7310MP

10kVA Medium Power Transformerless UPS