This series has an output power factor up to 0.9 and extended battery life. It has Versatile LCD human-computer interface. CN7001MPI/CN7001MPE model has high power density and battery backup.
Overview Specifications Ordering Information
This series has an output power factor up to 0.9 and extended battery life. It has Versatile LCD human-computer interface. CN7001MPI/CN7001MPE model has high power density and battery backup.
GENERAL FEATURES
|
|
Model | CN7001MPI/CN7001MPE | ||
Capacity |
VA |
1000 |
|
Watts |
900 |
||
Phase |
Single phase with ground |
||
Input |
Normal Voltage |
208/220/230/240Vac | |
Operating Voltage Range | 110~300Vac | ||
Frequency Range |
45~55Hz/55~65Hz (Auto-detect) |
||
Power Factor |
≥0.99 @Nominal voltage(100% load) |
||
Output |
Output Voltage |
208/220/230/240Vac | |
Power Factor |
0.9 |
||
Voltage Regulation |
±1% |
||
Frequency |
Line mode |
45~55Hz / 56~64Hz | |
Bat. mode |
50Hz / 60Hz ±0.1Hz |
||
Crest Factor |
3:1 |
||
Harmonic Distortion (THDv) |
≤3% THD(Linear load) |
||
≤5% THD(Non-linear load) |
|||
Transfer time |
AC to DC |
Zero | |
Inverter to bypass |
4ms(Typical) |
||
Waveform |
Pure sinewave |
||
Efficiency |
AC Mode |
88% |
|
Battery Mode |
85% |
||
Battery |
Internal |
Battery Type |
12V/9AH |
Numbers |
2 3 |
||
Backup time |
»5 minutes, remaining time displayed on the LCD |
||
Typical Recharging Time |
4 hours recover to 90% capacity |
||
Charging current(max.) |
1.0A |
||
Charging Voltage |
27.4Vdc ±1%/ 41.1Vdc ±1% 41.1Vdc ±1% |
||
Battery |
External |
Battery Numbers |
2 3 |
Charging Voltage |
27.4Vdc ±1% 27.4Vdc ±1% |
||
Backup time |
6A/12A 6A/12A |
||
Indicators |
LCD |
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators | |
Alarm |
Battery Mode |
Beeping every 4 seconds | |
Battery Low |
Beeping every second |
||
Overload |
Beeps twice p second |
||
Fault |
Continously beeping |
||
Physical |
Dimension |
Standard model |
144x300x209 |
Long run model |
144x300x209 |
||
Weight |
Standard model |
9.5/13 |
|
Long run model |
4.1 |
||
Environment |
Humidity |
20-90% RH @ 0-40°C (Non-condensing) | |
Noise level |
<50dB @ 1 Meter |
||
Management |
Smart RS232/USB |
Supports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux, FreeBSD and MAC | |
Optional SNMP |
Power management from SNMP manager and web browser |
Specifications are subject to change without prior notice
EXTERNAL BATTERY PACK | ||
Model | CNBC00124CT | CNBC00136CT |
BATTERY SYSTEM | ||
Battery Type |
VRLA (Lead acid maintenance free battery) |
|
Typical battery recharging time | 6~8 hours (to 90% of full capacity) | |
Typical Battery Life | 3~5 years, depend on discharging cycle and ambient temperature | |
System Voltage |
24Vdc |
36Vdc |
Charging Current Max | 1.4A | 1.4A |
Battery quantity | 4 | 6 |
Capacity |
9Ah/12V (7Ah/12V optional |
|
Backup time @ 50% load | 16 minutes 30 minutes | |
Backup time @ 100% load | 6 minutes 12 minutes | |
PHYSICAL | ||
Dimension W x D x H (mm) | 144 x 399 x 209 | |
Net weight(kg) | 13.5 18.5 | |
ENVIRONMENT | ||
Safety | CE | |
Operating environment | 0°C~40°C | |
Relative humidity | 0~95% (Non condensing) | |
Noise Level | <40dB at 1 Meter |
Part Number | Description | ||
CN7001MPI |
1kVA Medium Power Transformerless UPS (Internal battery) |
||
CN7001MPE |
1kVA Medium Power Transformerless UPS (External battery) |
||
CNBC00124CT |
24 VDC Battery Pack |
||
CNBC00136CT |
36 VDC Battery Pack |