MAXPOWER is a small to medium power transformer-less UPS of CellNor. This UPS has a high output power factor at 0.9PF and a wide input voltage range: 120~276Vac. The CN7006MPI/CN7006MPE model support economic (ECO) operation mode.
Overview Specifications Ordering Information
GENERAL FEATURES
|
|
Model | CN7006MPI/CN7006MPE | |
Capacity |
VA |
6000 |
Watts |
5400 |
|
Input |
Normal Voltage | 220/230/240Vac |
Operating Voltage Range |
110~286Vac |
|
Operating Frequency Range |
40~70Hz (50/60Hz Auto-Sensing) |
|
Power Factor |
≥0.99 |
|
Bypass voltage range |
Max.voltage:230~264Vac Min.voltage:176~220Vac |
|
ECO Range | Same as the bypass | |
Harmonic distortion (THDi) | <3%(100% linear load | |
Generator Input | Support | |
Output |
Rated voltage | 220/230/240Vac |
Power Factor |
0.9 |
|
Voltage Regulation |
±1% |
|
Freq. Line mode |
±10% of the rated frequency | |
Freq. Bat. mode |
50Hz / 60Hz (±0.1)Hz |
|
Crest Factor |
3:1 |
|
Harmonic Distortion (THDv) |
≤2% with linear load, ≤5% with non-linear load |
|
Efficiency |
>93.5% |
|
Output Waveform | Pure Sine Wave | |
Battery |
Battery Voltage |
(Standard unit 240Vdc) 192/216/240Vdc (Adjustable) |
Capacity (Standard unit) |
9Ah/12V (7Ah/12V optional) |
|
Typical recharging Time |
6~8 hours (to 90% of full capacity) |
|
Charging current |
1A(Standard unit); Long run unit Max.current 8A(charging current can be set according to battery capacity installed) |
|
System features |
Transfer time | Mains to battery:0ms; Mains to bypass:0ms |
Overload |
Line mode : Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediately Bypass mode: 40A(Breaker) |
|
Short circuit |
Hold whole system |
|
Overheat |
Line mode: Turn to bypass; Backup mode: shut down UPS immediately |
|
Battery low | Alarm and switch off | |
Self-diagnostics | Upon power on and software control | |
Battery | Advanced battery management | |
Audible & Visual alarms | Line failure, Battery under voltage, Overload, System fault | |
LED and LCD Display | Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS Fault | |
LCD Display | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time | |
Communication interface | RS232, USB,SNMP card(optional), Parallel card(optional), Relay card (optional) | |
Environment |
Operating temperature |
0~40°C |
Storage temperature |
-25~55°C |
|
Humidity range |
0~95% (Non-condensing) |
|
Altitude |
<1500m |
|
Noise Level | <55d | |
Standards |
Safety | IEC/EN62040-1,IEC/EN62477-1 |
EMC |
IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
|
Physical |
Dimension | I:191 x 460 x 720 E:191 x 460 x 337 |
Net Weight (kg) |
69 12 |
Specifications are subject to change without prior notice
EXTERNAL BATTERY PACK | |
Model | CNBC06120CT |
Battery Type |
VRLA (Lead acid maintenance free battery) |
Typical battery recharging time | 6~8 hours (to 90% of full capacity) |
Typical Battery Life | 3~5 years, depend on discharging cycle and ambient temperature |
System Voltage |
240Vdc |
Battery Qty | 2*20 pcs |
Capacity |
7Ah/9Ah (12V) |
Backup time @ 50% load | 43 minutes |
Backup time @ 100% load | 15 minutes |
Dimension(WxDxH) | 250 x 597 x 616 |
Net weight(kg) | 122/134 |
Environment safety | CE |
Operating environment | 0°C~40°C |
Relative humidity | 0~95% (Non condensing) |
Noise Level | <40dB at 1 Meter |
Part Number | Description | ||
CN7006MPI |
6kVA Medium Power Transformerless UPS (Internal battery) |
||
CN7006MPE |
6kVA Medium Power Transformerless UPS (External battery) |
||
CNBC06120CT |
120 VDC Battery Pack |