NORDEN FireNor PH30 Fire resistant cables are manufactured within the specific requirement of Fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor Fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centers, airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gases.
Overview Specifications Ordering Information
NORDEN FireNor PH30 Fire resistant cables are manufactured within the specific requirement of Fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor Fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centers, airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gases.
ConductorAnnealed Copper wires (Class 5) |
ScreenAL/PET Foil |
Drain Wire0.8mm Solid Aluminium |
InsulationSilicone Rubber |
SheathLSZH,Type LTS3 |
Sheath ColorRed/White |
Insulation Colour2 Core: Brown and Blue |
Standard Packing Mode100 mtr / Plywood Reel 500 mtr / Plywood Reel (optional) |
Flame Tests | Insulation Integrity | Smoke Density | Corrosive Gases Measurement |
IEC 60332-1-2 |
EN 50200 PH 30 ANNEXE |
IEC 61034-1/2 |
IEC 60754-1/2 |
Properties | Value | |
1.0 mm² | 1.5 mm² | |
Max. Conductor Resistant @ 20ºC |
19.5 Ω/km |
13.30 Ω/km |
Min. Insulation Resistant @ 0ºC |
200 MΩxkm |
|
Operating Voltage |
300/500 V |
|
Test Voltage |
2000 V |
|
Temperature Range (Operation) |
-30ºC to + 180ºC |
|
Temperature Range (Installation) |
-5ºC to + 50ºC |
|
Min. Bend Radius |
8 x D |
Nom. Cond. Cross-Sect. mm² |
Cable Diameter mm (±2 %) | Cable Weight Kg/km |
2 x 1.0 |
5.80 |
44.90 |
2 x 1.5 |
6.65 |
59.60 |
Part Number | Description |
5J-1002XY |
PH30 Stranded Conductor Shielded Fire Resistant Cable, 2C x 1.0 mm² |
5J-1502XY |
PH30 Stranded Conductor Shielded Fire Resistant Cable, 2C x 1.5 mm² |
X (Colour code) > RD:Red WH:White
Y (Packing length) > 1:100mtr, 2: 500mtr