RG 59U Coaxial Cable...

RG 59U Coaxial Cable 75 Ohm TC Braid 95% Coverage

Norden RG 59U is used for video transmission in professional video applications, carrying either baseband analog video signals in closedcircuit television (CCTV) or serial digital interface (SDI) system using 75 ohm coaxial cables. It can also be used as Analog Video Cable. The center conductor is ordinarily solid copper, the shielding is much heavier (typically aluminium foil/ 95% Tinned copper braid), and tolerances are more tightly controlled, to improve impedance stability.RG59 can be used as a branch cable with Standard Transmission distance up to 300m.


Overview Specifications Ordering Information

Overview

Norden RG 59U is used for video transmission in professional video applications, carrying either baseband analog video signals in closedcircuit television (CCTV) or serial digital interface (SDI) system using 75 ohm coaxial cables. It can also be used as Analog Video Cable. The center conductor is ordinarily solid copper, the shielding is much heavier (typically aluminium foil/ 95% Tinned copper braid), and tolerances are more tightly controlled, to improve impedance stability.RG59 can be used as a branch cable with Standard Transmission distance up to 300m.

Specifications

 

Conductor

Bare Copper

Insulation Color

Neutral

Braid Wire

TC Wire

Jacket Color

Black

Insulation

Foam PE (Polyethylene)

Shielding

Aluminium/Polyester Foil
Bonded

Outer Jacket

PVC (Polyvinyl Chloride)

 

PHYSICAL CHARACTERISTICS

Characteristic Value

Center Conductor Diameter

0.81 mm

Insulation Diameter

3.71 mm

Braid Wire Diameter

0.12 mm

No. of Braid Wire

144

Braid Wire Coverage

95%

Outer Jacket Diameter

6.15 mm

Min. Bending Radius (Installation)

18.55 mm

Max. Pulling Tension

372N

Operating Temperature

-20°C to +75°C

 

ELECTRICAL CHARACTERISTICS

Characteristic Unit Value

Characteristic Impedance

Ω

75.0

Capacitance

pF/m

52.0

Center Conductor DCR

Ω/km

<34

Braid Wire DCR

Ω/km

<13

Velocity of Propagation

%

84

Dielectric Strength

VCA

1000

Jacket Sparker

VCA

2500

Return Loss (5-6000 MHz)

dB

18.0

PERFORMANCE CHARACTERISTICS

Frequency at 20°C
(MHz)
Attenuation (10% higher)
(dB/100m)

1

0.93

10

3.20

100

10.63

400

22.39

700

30.65

900

35.67

1000

37.15

RoHS GUIDELINE

Properties Value

Calcium Content (Cd)

0.01%

Lead Content (Pb)

0.1%

Mercury Content (Hg)

0.1%

Chromium (VI) Content

0.1%

Polybrominated Biphenyls (PBB)

Forbidden

Polybrominated Diphenyl Ether (PBDE)

Forbidden

 

Ordering Information