SOLAR EXTERNAL CABLE XL-LSZH

Norden Solar cables are designed as per EN 50618 & IEC 62930(ed. 1) for permanent external applications. These cables are constructed with cross-linked low smoke zero halogen insulation & jacket. Which makes cable weather & UV resistant for harsh environment installations, especially for the interconnection of grounded and undergrounded photovoltaic Power Systems.


Overview Specifications Ordering Information

Overview

Norden Solar cables are designed as per EN 50618 & IEC 62930(ed. 1) for permanent external applications. These cables are constructed with cross-linked low smoke zero halogen insulation & jacket. Which makes cable weather & UV resistant for harsh environment installations, especially for the interconnection of grounded and undergrounded photovoltaic Power Systems.

Specifications

CABLE CONSTRUCTIONS

Conductor

Stranded Tinned Copper

Outer Jacket

XLPE LSZH

Reference Standard

EN50618:2014

IEC 62930(ed.1) 

Insulation

XLPE LSZH 

Jacket Color

Black/Red

 

 

PHYSICAL CHARACTERISTICS

Characteristic Value      

No. of Conductor

1 Core

     

Conductor Size

2.5mm ² (48/0.25mm)

4mm² (56/0.285mm) 6mm² (78/0.3mm)  10mm² (74/0.4mm)

Conductor Diameter

2mm

2.6mm 3.2mm 4mm

Conductor Resistance

8.21Ω/km@20℃

5.09Ω/km@20C 3.39Ω/km@20C 1.95Ω/km@20C

Insulation Thickness

0.75mm

0.85 0.9 1.0

Insulation Diameter

3.5±0.2mm

4.4±0.2mm 5.0±0.2mm  6.0±0.2mm
Nom. Jacket Thickness 0.9mm  0.85mm 1.0mm 0.9mm
Nom. Outer Cable Diameter 5.4±0.2mm 6.1±0.2mm 7.0±0.2mm 7.8±0.2mm
 
MECHANICAL & ENVIRONMENTAL CHARACTERISTICS
Characteristic Value

Temperature Range (fixed installation )

-40°C to +120°C

Ambient Temperature  -40°C to +90°C 

Minimum bending radius (flexing)

15xOD

Minimum bending radius (fixed)

5xOD

Weathering/UV-resistance

EN60811-501

Ozone Resistance

EN 50396

Halogen Free

EN50525-1

Smoke Density

EN61034-2

Flame Retardant

IEC 60332-1-2

 

ELECTRICAL CHARACTERISTICS

Characteristic Unit Value

Rated Voltage

V

AC 1000 DC 1500 

Rated current

Amp

50

Max. Operating Voltage

V

 DC 1800 V(EN 50618)

Dielectric Strength (AC)

KV/5Min

6.5

Current carrying capacity - EN 50618

Ordering Information

Part Number Description

89-60056801X

2mm² Solar External Cable XL-LSZH

89-60056901X 4mm² Solar External Cable XL-LSZH
89-60056A01X 6mm² Solar External Cable XL-LSZH
89-60056B01X 10mm² Solar External Cable XL-LSZH